||= Version =||= MinHW =||= Date =||= Done by =||= Reason =|| || ||04.00 || 1 ||2016/04/12||mvdeventer ||New form factor and LCD || ||04.01 || 1 ||2016/04/12||mvdeventer ||LCD driver updates|| ||04.02 || 1 ||2016/04/18||mvdeventer ||Add SDO 200 to turn on/off LCD ALL, for testing|| ||04.03 || 1 ||2016/04/26||mvdeventer ||Remove Rickard LOGO from button press on startup|| ||04.04 || 1 ||2016/05/03||mvdeventer ||Fix comms, prevent collision on the start bit|| ||04.05 || 1 ||2018/05/24||mvdeventer ||Fix setup menu SDO not send to correct device type (Onboard master)|| ||04.06 || 1 ||2018/05/24||mvdeventer ||First CO2 version,don't work with occupancy sensor|| ||04.07 || 1 ||2018/05/24||mvdeventer ||Fix min max value from SDO 57|| ||04.08 || 1 ||2018/12/05||mvdeventer ||Update for new (fancoil) LCD \\Implement CO2 comfort control \\Implement CO2 control \\Limit CO2 value to 1999 ppm|| ||04.09 || 1 ||2019/07/16||mvdeventer ||Make occupancy sensor work again|| ||04.10 || 1 ||2019/07/16||mvdeventer ||Fix occupancy timeout|| ||04.11 || 1 ||2019/07/17||mvdeventer ||Only read occupancy sensor if diffuser comms is idle(prevent possible false triggers)|| ||04.12 || 1 ||2019/08/08||mvdeventer ||Rework occupancy delays 1 and 2. If the delay is set 0 don't do the action|| ||04.13 || 1 ||2019/08/12||mvdeventer ||Occupancy Icon must be on when "OccupancyOverride" is to "occupied"|| ||04.14 || 1 ||2019/11/21||mvdeventer ||Flash CO2 top left when CO2 override active \\Add CO2 Menus to display current CO2, CO2 setpoint high and CO2 setpoint low|| ||04.15 || 1 ||2020/06/05||mvdeventer ||Reduce noise in changeover sensor samples|| ||04.16 || 1 ||2020/10/14||mvdeventer ||First relative humidly(RHT) sensor release|| ||04.17 || 1 ||2020/10/20||mvdeventer ||Add error recovery for RHT readings|| ||04.18 || 1 ||2020/10/22||mvdeventer ||Add RHT display setup bit|| ||04.19 || 1 ||2020/12/17||mvdeventer ||Corrected network startup time, needed for Fancoil MultiZone compatibility|| ||04.19 || 1 ||2020/12/17||mvdeventer ||Do not display CO2 or RHT in menus if they are not installed|| ||04.20 || 1 ||2021/02/24||mvdeventer ||Implement new CO2 sensor || ||04.20 || 1 ||2021/02/24||mvdeventer ||Add override status SDO 75(CO2 or RHT override)|| ||04.20 || 1 ||2021/02/24||mvdeventer ||Fix Blank LCD srceen (defect report:BT0061-0001)|| ||04.20 || 1 ||2021/02/24||mvdeventer ||Set default occupancy delays to 0|| ||04.20 || 1 ||2021/02/24||mvdeventer ||Display override values(CO2 or RHT) when in override on LCD|| ||04.21 || 1 ||2021/03/01||mvdeventer ||Changes for production process when CO2 is fitted|| ||04.21 || 1 ||2021/03/01||mvdeventer ||Fix CO2 sensor comms|| ||04.22 || 1 ||2021/03/12||christo.malan||Add some network lock functions(not used)|| ||04.23 || 1 ||2021/03/12||mvdeventer ||Fix compatibly with old CO2 and occupancy sensors|| ||04.24 || 1 ||2021/03/23||mvdeventer ||Limit CO2 LCD displayed to 1999|| ||04.25 || 1 ||2021/03/24||mvdeventer ||Changes for production process when CO2 is fitted||