||= Version =||= MinHW =||= Date =||= Done by =||= Reason =||
||2.00 || ||2012/09/25 ||martin.vdeventer || EMC and EMI Test qualification firmware for RF Wallstat and RF Access Point ||
||2.04 || ||2012/09/28 ||martin.vdeventer || EMC and EMI Test qualification firmware for RF Wallstat and RF Access Point ||
|| || || || || Permanent carrier WS and AP ||
||3.00 || ||2012/10/05 ||martin.vdeventer || EMC and EMI Test qualification firmware for RF Wallstat and RF Access Point ||
|| || || || || 0 - OFF ||
|| || || || || 1 - 868.050MHz ||
|| || || || || 2 - 868.150MHz ||
|| || || || || 3 - 868.250MHz ||
|| || || || || 4 - 868.350MHz ||
|| || || || || 5 - 868.450MHz ||
|| || || || || 6 - 868.550MHz ||
||4.00 || ||2012/11/20 ||martin.vdeventer || Port to new MSP430F5328 CODEB_ISR msp430 delay cross_studio_io print puts ||
||4.01 || ||2012/11/20 ||martin.vdeventer || NOTE: 1 must be for (i = 0; i < SegCnt; i++) and not for (i = 0; i < SegCnt; SegCnt++) ||
||4.02 || ||015/07/06 ||martin.vdeventer || itial Code for new Rickard RF WALLSTAT and ACCESSPOINT ||
||4.03 || ||2015/08/18 ||martin.vdeventer || AP PDO for TC 6 added ||
|| || || || || save to flash MFRI network on AP. Load from ram ||
|| || || || || button press to initiate join ||
|| || || || || Note 1: Changed in bsp_board.c "BSP_TIMER_CLK_MHZ*usec;" to "32 *usec;" ||
||4.04 || ||2015/10/09 ||martin.vdeventer || Working 15 Wallstats but with uMsg Comms still iffy if Link Mode ||
||4.05 || ||2015/10/09 ||martin.vdeventer || NOTE: 2 Changed LINKLISTEN_MILLISECONDS_2_WAIT from 5000 to 100 and ||
|| || || || || Solved uMsg Comms fail when Linking ||
||4.06 || ||2015/11/13 ||martin.vdeventer || NOTE 3: Can not increment counter here, will cause poll to skip Onboard MAster ||
||4.07 || ||2016/05/19 ||martin.vdeventer || Add RSSI and Battery Volts SDO's for RF Wallstat on AP and RSSI display on RF Wallstat ||
||4.08 || ||2016/05/19 ||martin.vdeventer || Immediate Peer Address Save to RAM when device receive's link from ED ||
|| || || || || Add VCC and RSSI PDO FC 5 to RF Wallstat ||
||4.09 || ||2016/05/26 ||martin.vdeventer || NOTE: 4.09.1 Fix the reset/startup hang added XT1HFOFFG in flags to clear and also added delay ||
|| || || || || before checking and clearing the flags again ||
|| || || || || NOTE: 4.09.2 Poll the wallstats as they come in ||
|| || || || || NOTE: 4.09.3 Add the RF ED_TYPE and RF ED_FW_VER also to the PDO out of the WALLSTAT ||
||4.10 || ||2016/06/09 ||martin.vdeventer || Add chang over cope to other WS from enabled wallstat change over ||
||4.17 || ||2016/09/29 ||martin.vdeventer || Update Frequency from 868.150MHZ with 150KHz steps and 7 channels. ||
||4.18 || ||2017/02/10 ||martin.vdeventer || //REMOVED: NOTE: 4.09.2 Poll the wallstats as they come in ||
||4.19 || ||2017/02/24 ||martin.vdeventer || //Just some code mods ||
|| || || || || Various Firmware updates ||
|| || || || || Enable Setpoint display on WS ||
|| || || || || 1 minute interval transmit from WS if temp spec for heating or cooling met ||
|| || || || || 10 minute maximum transmit interval ||
|| || || || || implemented SDO 50 read for virtual WS on AP ||
||4.20 ||2 ||2017/02/24 ||martin.vdeventer || Changed RF_COMMS_TX_INTERVAL_MAX from 30 to 660 seconds ||
||4.21 ||2 ||2017/02/24 ||martin.vdeventer || Changed RF_COMMS_TX_INTERVAL_MAX from 660 to 660*2 seconds ||
||4.22 ||2 ||2017/04/04 || || NOTE: 11 NWK_REPLY_DELAY(); x 4 to solve missing packets ||
||4.23 ||2 ||2017/04/04 || || NOTE: 11 NWK_REPLY_DELAY(); x 1 to solve missing packets ||
||4.24 ||2 ||2017/06/27 ||martin.vdeventer || NOTE: 12 Disable Temp copy to CO ||
||4.25 ||2 ||2017/07/16 ||martin.vdeventer || NOTE: 13 Disable CO by default ||
||4.26 ||2 ||2017/08/23 ||martin.vdeventer || NOTE: 14 if no serial then loop must be 0 ||
||4.27 ||2 ||2017/08/23 ||martin.vdeventer || NOTE: 15 Commissioning mode ||
|| || || || || NOTE: 16 Send back the Min and Max Setpoint to RF device ||
|| || || || || NOTE: 17 This is to ensure that the setpoint is in limitswhen recevied via poll from end device ||
|| || || || || NOTE: 18 Each time a message is received from ED the MIN and MAX SP to ED wil be aupdated ||
||4.28 ||2 ||2017/09/06 ||martin.vdeventer || changed RF_COMMISSION_TIME to 30 minutes = 1800seconds ||
||4.29 ||2 ||2017/09/12 ||martin.vdeventer || change VOLTAGE_LOW_2_6 to VOLTAGE_LOW_2_8V ||
||4.30 ||2 ||2017/09/15 ||martin.vdeventer || Added SDO 63 Commision Mode Timeout ||
||4.31 ||2 ||2017/10/05 ||martin.vdeventer || NOTE: 18 Change Over must be default 0 ||
|| || || || || NOTE: 19 default all NodeInfo values here ||
||4.32 ||2 ||2017/10/18 ||martin.vdeventer || NOTE: 20 Add Vcc/Rssi/Timeout to Wallstat PDO in byte 8 of PDO ||
|| || || || || ICASA EMC TESTS FOR 920MHZ AP WS POD ||
||4.33 ||2 ||2017/11/14 ||martin.vdeventer || NOTE: 21 Bootloader update ||
|| || || || || ||
|| || || || || ||
||4.34 ||2 ||2017/11/16 ||martin.vdeventer || NOTE: 22 ||
|| || || || || Split ProcDataAP and ProcdataWS ||
|| || || || || ProcDataAP to InfoB ||
|| || || || || ProcDataWS to PROCDATA ||
||4.35 ||2 ||2017/11/23 ||martin.vdeventer || NOTE 20: cahnge Comm time out flag to set when 60s more than EDCommsTimeMax ||
||4.36 ||2 ||2018/03/05 ||martin.vdeventer || CONFIRMED EIRP levels at ISERT for 920MHZ to be below 3mW ||
||4.37 6.37 ||2 ||2018/03/20 ||martin.vdeventer || 868MHz release firmware ||
|| || || || || Added support for compile time for FW_VERSION to be 4.xx for 868MHz and 6.xx for 920MHz ||
|| || || || || Added FIRMWARE_868_MAJOR ||
|| || || || || Added FIRMWARE_920_MAJOR ||
|| || || || || Added FIRMWARE_MINOR ||
||4.38 6.38[[BR]] ||2 ||2018/08/28 ||martin.vdeventer || Add reset again when there is no Diffuser Controller ||
||4.39 6.39 ||2 ||2018/09/13 ||martin.vdeventer || Dont write to flash when erasing or refreshing network. Make the commission mode for 1 hour instead of 30min.[[BR]] ||
||4.40 6.40 ||2 ||2018/09/17 ||martin.vdeventer ||enable watchdog timer again||