Version 5 (modified by 4 years ago) (diff) | ,
---|
Issue: 4
Version | MinHW | Date | Done by | Reason |
---|---|---|---|---|
1.00 | 2018/07/18 | gavin.mutch | First Major Release | |
1.01 | 2018/08/01 | gavin.mutch | Fixed change-over heating/cooling bug | |
1.02 | 2018/08/02 | gavin.mutch | Added support for setpoint/sense temperature sharing between Fan Coils via Loop Number | |
1.04 | 02/08/2018 | gavin.mutch | Found the previous bug was not fully fixed. Fixed an issue where OFF had highest priority, but showed up as overriden when an input was triggered. | |
1.05 | 07/08/2018 | gavin.mutch | Included SDO 48 (Occupancy override) for Christo. | |
1.06 | 29/11/2018 | christo.malan | Fix loop jumping | |
1.07 | 09/02/2019 | christo.malan | Add rundown timer, keep fan on if heater was on. Fix Manual Fan and Auto valve mode. | |
1.20 | 18/06/2020 | christo.malan | Major Update: Minimum Wallstat Version is 8.08 Add new valve modes 2-10V and 6 way valve Use change over for both valves. Fix heater, only switch on after the hot valve opened. Add Multi Zone control: Use average diffuser temperature and setpoint and control fan speed based on average diffuser disk. Minimum diffuser wallstat version is 4.19 for Multi Zone | |
1.21 | 21/08/2020 | christo.malan | fix valve change over operation Keep heater off if not in use Implement heater minimum Off time (if switched off keep it off for minimum of 15s) | |
1.22 | 14/09/2020 | christo.malan | Fix fan speed sdo, use fan % and not step fix 1s timeout for inputs, move code to interrupt fix demo temp not updated in pdo Always update fan speed in Mulitzone mode fix fan rundown, reload as long as mode is not off fix fan max | |
1.23 | 29/09/2020 | christo.malan | Add, Calculate EC fan speed from diffusers if temperature is < 0.5C, no sensor, switch off heater fix use fanspeed for Aux and OCC mode add fallback mode for noDiffusers and noMaster remove compiler warnings detect that an other device is polling and reset Fix, only set noDiffuer if Multi Zone is enabled | |
1.24 | 13/10/2020 | christo.malan | Recalled Fix network startup timing. Prevent unoccupied mode from switching the unit on. | |
1.25 | 02/11/2020 | christo.malan | Fix overflow in diffuser control fan speed Fix min fan speed for PI output of 0% Load PI settings during upgrade set to defaults and if 0. | |
1.26 | 06/11/2020 | christo.malan | Remove "fix network startup timing" added in V1.24. Fixed with diffuser wallstat version 4.19. |