Changes between Initial Version and Version 1 of RelTest


Ignore:
Timestamp:
11/23/17 12:25:38 (8 years ago)
Author:
Christo
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • RelTest

    v1 v1  
     1||= Version =||= MinHW =||= Date =||= Done by =||= Reason =||
     2||2.00 || ||2012/09/25 ||martin.vdeventer || EMC and EMI Test qualification firmware for RF Wallstat and RF Access Point ||
     3||2.04 || ||2012/09/28 ||martin.vdeventer || EMC and EMI Test qualification firmware for RF Wallstat and RF Access Point ||
     4|| || || || || Permanent carrier WS and AP ||
     5||3.00 || ||2012/10/05 ||martin.vdeventer || EMC and EMI Test qualification firmware for RF Wallstat and RF Access Point ||
     6|| || || || || 0 - OFF ||
     7|| || || || || 1 - 868.050MHz ||
     8|| || || || || 2 - 868.150MHz ||
     9|| || || || || 3 - 868.250MHz ||
     10|| || || || || 4 - 868.350MHz ||
     11|| || || || || 5 - 868.450MHz ||
     12|| || || || || 6 - 868.550MHz ||
     13||4.00 || ||2012/11/20 ||martin.vdeventer || Port to new MSP430F5328         CODEB_ISR msp430 delay cross_studio_io print puts ||
     14||4.01 || ||2012/11/20 ||martin.vdeventer || NOTE: 1        must be for (i = 0; i < SegCnt; i++) and not for (i = 0; i < SegCnt; SegCnt++) ||
     15||4.02 || ||015/07/06 ||martin.vdeventer || itial Code for new Rickard RF WALLSTAT and ACCESSPOINT ||
     16||4.03 || ||2015/08/18 ||martin.vdeventer || AP PDO for TC 6 added ||
     17|| || || || || save to flash MFRI network on AP. Load from ram ||
     18|| || || || || button press to initiate join ||
     19|| || || || || Note 1: Changed in bsp_board.c "BSP_TIMER_CLK_MHZ*usec;" to "32 *usec;" ||
     20||4.04 || ||2015/10/09 ||martin.vdeventer || Working 15 Wallstats but with uMsg Comms still iffy if Link Mode ||
     21||4.05 || ||2015/10/09 ||martin.vdeventer || NOTE: 2 Changed LINKLISTEN_MILLISECONDS_2_WAIT from 5000 to 100 and ||
     22|| || || || || Solved uMsg Comms fail when Linking ||
     23||4.06 || ||2015/11/13 || martin.vdeventer || NOTE 3: Can not increment counter here, will cause poll to skip Onboard MAster ||
     24||4.07 || ||2016/05/19 || martin.vdeventer || Add RSSI and Battery Volts SDO's for RF Wallstat on AP and RSSI display on RF Wallstat ||
     25||4.08 || ||2016/05/19 || martin.vdeventer || Immediate Peer Address Save to RAM when device receive's link from ED ||
     26|| || || || || Add VCC and RSSI PDO FC 5 to RF Wallstat ||
     27||4.09 || ||2016/05/26 || martin.vdeventer || NOTE: 4.09.1 Fix the reset/startup hang added XT1HFOFFG in flags to clear and also added delay ||
     28|| || || || || before checking and clearing the flags again ||
     29|| || || || || NOTE: 4.09.2 Poll the wallstats as they come in ||
     30|| || || || || NOTE: 4.09.3 Add the RF ED_TYPE and RF ED_FW_VER also to the PDO out of the WALLSTAT ||
     31||4.10 || ||2016/06/09 || martin.vdeventer || Add chang over cope to other WS from enabled wallstat change over ||
     32||4.17 || ||2016/09/29 || martin.vdeventer || Update Frequency from 868.150MHZ with 150KHz steps and 7 channels. ||
     33||4.18 || ||2017/02/10 || martin.vdeventer || //REMOVED:  NOTE: 4.09.2 Poll the wallstats as they come in ||
     34||4.19 || ||2017/02/24 || martin.vdeventer || //Just some code mods ||
     35|| || || || || Various Firmware updates ||
     36|| || || || || Enable Setpoint display on WS ||
     37|| || || || || 1 minute interval transmit from WS if temp spec for heating or cooling met ||
     38|| || || || || 10 minute maximum transmit interval ||
     39|| || || || || implemented SDO 50 read for virtual WS on AP ||
     40||4.20 ||2 ||2017/02/24 || martin.vdeventer || Changed RF_COMMS_TX_INTERVAL_MAX from 30 to 660 seconds ||
     41||4.21 ||2 ||2017/02/24 || martin.vdeventer || Changed RF_COMMS_TX_INTERVAL_MAX from 660 to 660*2 seconds ||
     42||4.22 ||2 ||2017/04/04 || || NOTE: 11 NWK_REPLY_DELAY(); x 4 to solve missing packets ||
     43||4.23 ||2 ||2017/04/04 || || NOTE: 11 NWK_REPLY_DELAY(); x 1 to solve missing packets ||
     44||4.24 ||2 ||2017/06/27 || martin.vdeventer || NOTE: 12 Disable Temp copy to CO ||
     45||4.25 ||2 ||2017/07/16 || martin.vdeventer || NOTE: 13 Disable CO by default ||
     46||4.26 ||2 ||2017/08/23 || martin.vdeventer || NOTE: 14 if no serial then loop must be 0 ||
     47||4.27 ||2 ||2017/08/23 || martin.vdeventer || NOTE: 15 Commissioning mode ||
     48|| || || || || NOTE: 16 Send back the Min and Max Setpoint to RF device ||
     49|| || || || || NOTE: 17 This is to ensure that the setpoint is in limitswhen recevied via poll from end device ||
     50|| || || || || NOTE: 18 Each time a message is received from ED the MIN and MAX SP to ED wil be aupdated ||
     51||4.28 ||2 ||2017/09/06 || martin.vdeventer || changed RF_COMMISSION_TIME to 30 minutes = 1800seconds ||
     52||4.29 ||2 ||2017/09/12 || martin.vdeventer || change VOLTAGE_LOW_2_6 to VOLTAGE_LOW_2_8V ||
     53||4.30 ||2 ||2017/09/15 || martin.vdeventer || Added SDO 63 Commision Mode Timeout ||
     54||4.31 ||2 ||2017/10/05 || martin.vdeventer || NOTE: 18 Change Over must be default 0 ||
     55|| || || || || NOTE: 19  default all NodeInfo values here ||
     56||4.32 ||2 ||2017/10/18 || martin.vdeventer || NOTE: 20 Add Vcc/Rssi/Timeout to Wallstat PDO in byte 8 of PDO ||
     57|| || || || || ICASA EMC TESTS FOR 920MHZ AP WS POD ||
     58||4.33 ||2 ||2017/11/14 || martin.vdeventer || NOTE: 21 Bootloader update ||
     59|| || || || || <MemorySegment size="0x6000" to size="0x6400" access="Read" start="0x8000" name="FLASH"/> ||
     60|| || || || || <MemorySegment size="0x400 " to size="0x800 " access="Read" start="0xE800" to start="0xE400" name="PROCDATA"/> ||
     61||4.34 ||2 ||2017/11/16 || martin.vdeventer || NOTE: 22 ||
     62|| || || || || Split ProcDataAP and ProcdataWS ||
     63|| || || || || ProcDataAP to InfoB ||
     64|| || || || || ProcDataWS to PROCDATA ||