    1 ||= Version =||= MinHW =||= Date =||= Done by =||= Reason =||   
    2 || 6.00||4|| 2011/11/22 ||mvdeventer    ||New version 4 hardware ||
    3 || 6.03||4|| 2012/12/05 ||mvdeventer    ||Updates for Lighting Control with wired light switch \\ Only do I2C comms (occupancy and flow) when the slave comms is idle||
    4 || 6.04||4|| 2013/13/01 ||mvdeventer    ||In chip Command Added again \\ Fix I2C comms sync \\ Add flow sensor functions ||
    5 || 6.05||4||2013/26/02  ||mvdeventer    ||Improve I2C occupancy comms \\Enable WDT, was off for debug \\ Rework Flow averaging calculation \\!LightSwitchChipIn - send occupancy status PDO immediately \\ Add overide indication\\ Remove Stratification mode again ||
    6 || 6.06||4||2013/26/02  ||mvdeventer    ||Add sdo to read occupancy sensor identification info ||
    7 || 6.07||4||2013/26/02  ||mvdeventer    ||Disable motor before reboot, to ensure that all motor off during a software update||
    8 || 6.08||4||2013/05/22  ||mvdeventer    ||Update bootloader to disable motor, to ensure that the motor is not drawing current in boot loader mode\\Rework the watchdog timer||
    9 || 6.09||4||2013/05/22  ||mvdeventer    ||**Recalled** control did not work\\  change occ sensitivity from 6 to 8 ||
    10 || 6.10||4||2014/02/24  ||mvdeventer    ||Fix 6.09 \\ Add intelligent (I2C) heater functionality, ensure the heater minimum on value is 10% \\ Add SDO 35 36 37 for flow control from MCU ||
    11 || 6.11||4||2014/03/30  ||mvdeventer    ||Add heater control bits, Control / Status heater control bits \\ Restore WDT ||
    12 || 6.12||4||2014/06/06  ||mvdeventer    ||Add Occupancy enable/disable(present) and Occupancy detected \\ Add Flow detected(sensor connected) ||
    13 || 6.13||4||2014/06/06  ||mvdeventer    ||Fix flow if no occupancy sensor is connected ||
    14 || 6.14||4||2015/01/19  ||mvdeventer    ||Correcty handle 0Pa reading from flow sensor \\ Don't do Control Override on Zone 0 ||
    15 || 6.15||4||2016/09/28  ||christo.malan ||Add heater control and other change over modes DM0073-0014 ||
    16 || 6.16||4||2017/11/13  ||mvdeventer    ||Added valve control for 24VAC Valves ||
    17 || 6.17||4||2019/07/25  ||christo.malan ||Stagger motor initialisation, prevent motors from hitting the endstop all at the same time (prevent power supply problems)||
    18 || 6.18||4||2019/11/19  ||christo.malan ||Add flow offset SDO ||
    19 || 6.19||4||2020/02/17  ||mvdeventer    ||Stability improvements for I2C code (Flow and Occupancy) \\ Rolling average on Flow/pressure value \\ Add software reset command for flow sensor error recovery|| 
    20 || 6.20||4||2020/04/02  ||christo.malan ||Remove flow updates from 6.19 \\ Disable button if pressed at startup. \\ Add sdo to show if it is disabled ||
    21 || 6.21||4||2020/06/22  ||christo.malan ||Add flow updates from 6.19 ||
    22 || 6.22||4||2020/07/24  ||christo.malan ||Clear flow connected flag if no sensor is connected \\ Add pressure test sdo 65 ||
    23 || 6.23||4||2021/03/18  ||christo.malan ||Add network lock(not used) \\Remove OCC chip in \\ Save button disable state in flash||
     1||= Version =||= MinHW =||= Date =||= Done by =||= Reason =||
     2|| 6.00|| 4 || 2011/11/22 ||mvdeventer ||New version 4 hardware ||
     3|| 6.03|| 4 || 2012/12/05 ||mvdeventer || Updates for Lighting Control with wired light switch \\ Only do I2C comms (occupancy and flow) when the slave comms is idle ||
     4|| 6.04|| 4 || 2013/13/01 ||mvdeventer ||In chip Command Added again \\ Fix I2C comms sync \\ Add flow sensor functions ||
     5|| 6.05|| 4 ||2013/26/02 ||mvdeventer ||Improve I2C occupancy comms \\Enable WDT, was off for debug \\ Rework Flow averaging calculation \\!LightSwitchChipIn - send occupancy status PDO immediately \\ Add overide indication\\ Remove Stratification mode again ||
     6|| 6.06|| 4 ||2013/26/02 ||mvdeventer ||Add sdo to read occupancy sensor identification info ||
     7|| 6.07|| 4 ||2013/26/02 ||mvdeventer || Disable motor before reboot, to ensure that all motor off during a software update ||
     8|| 6.08|| 4 ||2013/05/22 ||mvdeventer || Update bootloader to disable motor, to ensure that the motor is not drawing current in boot loader mode\\Rework the watchdog timer ||
     9|| 6.09|| 4 ||2013/05/22 ||mvdeventer ||**Recalled** control did not work\\  change occ sensitivity from 6 to 8 ||
     10|| 6.10|| 4 ||2014/02/24 ||mvdeventer ||Fix 6.09 \\ Add intelligent (I2C) heater functionality, ensure the heater minimum on value is 10% \\ Add SDO 35 36 37 for flow control from MCU ||
     11|| 6.11|| 4 ||2014/03/30 ||mvdeventer ||Add heater control bits, Control / Status heater control bits \\ Restore WDT ||
     12|| 6.12|| 4 ||2014/06/06 ||mvdeventer ||Add Occupancy enable/disable(present) and Occupancy detected \\ Add Flow detected(sensor connected) ||
     13|| 6.13|| 4 ||2014/06/06 ||mvdeventer ||Fix flow if no occupancy sensor is connected ||
     14|| 6.14|| 4 ||2015/01/19 ||mvdeventer ||Correcty handle 0Pa reading from flow sensor \\ Don't do Control Override on Zone 0 ||
     15|| 6.15|| 4 ||2016/09/28 ||christo.malan ||Add heater control and other change over modes DM0073-0014 ||
     16|| 6.16|| 4 ||2017/11/13 ||mvdeventer ||Added valve control for 24VAC Valves ||
     17|| 6.17|| 4 ||2019/07/25 ||christo.malan || Stagger motor initialisation, prevent motors from hitting the endstop all at the same time (prevent power supply problems) ||
     18|| 6.18|| 4 ||2019/11/19 ||christo.malan ||Add flow offset SDO ||
     19|| 6.19|| 4 ||2020/02/17 ||mvdeventer || Stability improvements for I2C code (Flow and Occupancy) \\ Rolling average on Flow/pressure value \\ Add software reset command for flow sensor error recovery ||
     20|| 6.20|| 4 ||2020/04/02 ||christo.malan ||Remove flow updates from 6.19 \\ Disable button if pressed at startup. \\ Add sdo to show if it is disabled ||
     21|| 6.21|| 4 ||2020/06/22 ||christo.malan ||Add flow updates from 6.19 ||
     22|| 6.22|| 4 ||2020/07/24 ||christo.malan ||Clear flow connected flag if no sensor is connected \\ Add pressure test sdo 65 ||
     23|| 6.23|| 4 ||2021/03/18 ||christo.malan || Add network lock(not used) \\Remove OCC chip in \\ Save button disable state in flash ||
     24|| 6.24|| 4 ||2021/04/09 ||christo.malan || Network Lock release DM0073-0015 ||
     25|| 6.25|| 4 ||2021/07/07 ||christo.malan || Add setting to report change over mode with a negative disk position. sdo 66 \\Make the changeover dead band a setting. sdo 66 \\ Mirror disk position at changeover ||
     26|| 6.26|| 4 ||2021/10/28 ||christo.malan || Fix occupancy trigger (Not working since V6.23) \\Remove - Mirror disk position at changeover added in V6.25\\ Hot start release DM0073-0018 ||