wiki:BtWallStat2

Version 6 (modified by Martin van Deventer, 2 years ago) (diff)

--

Version MinHW Date Done by Reason
04.00 1 2016/04/12 mvdeventer New form factor and LCD
04.01 1 2016/04/12 mvdeventer LCD driver updates
04.02 1 2016/04/18 mvdeventer Add SDO 200 to turn on/off LCD ALL, for testing
04.03 1 2016/04/26 mvdeventer Remove Rickard LOGO from button press on startup
04.04 1 2016/05/03 mvdeventer Fix comms, prevent collision on the start bit
04.05 1 2018/05/24 mvdeventer Fix setup menu SDO not send to correct device type (Onboard master)
04.06 1 2018/05/24 mvdeventer First CO2 version,don't work with occupancy sensor
04.07 1 2018/05/24 mvdeventer Fix min max value from SDO 57
04.08 1 2018/12/05 mvdeventer Update for new (fancoil) LCD
Implement CO2 comfort control
Implement CO2 control
Limit CO2 value to 1999 ppm
04.09 1 2019/07/16 mvdeventer Make occupancy sensor work again
04.10 1 2019/07/16 mvdeventer Fix occupancy timeout
04.11 1 2019/07/17 mvdeventer Only read occupancy sensor if diffuser comms is idle(prevent possible false triggers)
04.12 1 2019/08/08 mvdeventer Rework occupancy delays 1 and 2. If the delay is set 0 don't do the action
04.13 1 2019/08/12 mvdeventer Occupancy Icon must be on when "OccupancyOverride?" is to "occupied"
04.14 1 2019/11/21 mvdeventer Flash CO2 top left when CO2 override active
Add CO2 Menus to display current CO2, CO2 setpoint high and CO2 setpoint low
04.15 1 2020/06/05 mvdeventer Reduce noise in changeover sensor samples
04.16 1 2020/10/14 mvdeventer First relative humidly(RHT) sensor release
04.17 1 2020/10/20 mvdeventer Add error recovery for RHT readings
04.18 1 2020/10/22 mvdeventer Add RHT display setup bit
04.19 1 2020/12/17 mvdeventer Corrected network startup time, needed for Fancoil MultiZone? compatibility
04.19 1 2020/12/17 mvdeventer Do not display CO2 or RHT in menus if they are not installed
04.20 1 2021/02/24 mvdeventer Implement new CO2 sensor
04.20 1 2021/02/24 mvdeventer Add override status SDO 75(CO2 or RHT override)
04.20 1 2021/02/24 mvdeventer Fix Blank LCD srceen (defect report: BT0061-0001)
04.20 1 2021/02/24 mvdeventer Set default occupancy delays to 0
04.20 1 2021/02/24 mvdeventer Display override values(CO2 or RHT) when in override on LCD
04.21 1 2021/03/01 mvdeventer Changes for production process when CO2 is fitted
04.21 1 2021/03/01 mvdeventer Fix CO2 sensor comms
04.22 1 2021/03/12 christo.malan Add some network lock functions(not used)
04.23 1 2021/03/12 mvdeventer Fix compatibly with old CO2 and occupancy sensors
04.24 1 2021/03/23 mvdeventer Limit CO2 LCD displayed to 1999
04.25 1 2021/03/24 mvdeventer Changes for production process when CO2 is fitted
04.26 1 2021/04/26 christo.malan Network lock release DM0073-0015
04.27 1 2021/08/29 christo.malan Allow CO2 setpoint to be changed when set to always display CO2
Make setpoint edit time out after 5s
04.28 1 2021/10/28 christo.malan Hot start release DM0073-0018
04.29 1 2021/11/15 christo.malan Slowdown LCD temperature update
04.30 1 2021/11/15 martin.vdeventer Add NTC offset code
04.31 1 2021/11/15 martin.vdeventer ProcData?.b_USE_NTC_TEMP_SENSOR = TRUE USE THE NTC for temp measurements
04.32 1 2022/06/23 martin.vdeventer ProcData?.b_HumidityOffset implemented
04.33 1 2022/07/05 martin.vdeventer Menu Updates
04.33 1 2022/07/05 martin.vdeventer CO2 ventialtion setpoint can be set when the CO2 override is on screen
04.33 1 2022/07/05 martin.vdeventer Change RHT to RH on LCD
04.33 1 2022/07/05 martin.vdeventer Co2 setpoint high or temperature setpoint
04.34 1 2022/07/14 martin.vdeventer Flash setpoints only when SDO 50 Edit setpoint Disable is false else dont flash
04.34 1 2022/07/14 martin.vdeventer All LCD segment ON/OFF and flashing is done in lcd.c. Nothing in main loop
04.35 1 2022/07/10 martin.vdeventer Sensirion SCD30 I2C default read values when started and polling added