| Version 6 (modified by , 3 years ago) (diff) |
|---|
| Version | MinHW | Date | Done by | Reason |
|---|---|---|---|---|
| 04.00 | 1 | 2016/04/12 | mvdeventer | New form factor and LCD |
| 04.01 | 1 | 2016/04/12 | mvdeventer | LCD driver updates |
| 04.02 | 1 | 2016/04/18 | mvdeventer | Add SDO 200 to turn on/off LCD ALL, for testing |
| 04.03 | 1 | 2016/04/26 | mvdeventer | Remove Rickard LOGO from button press on startup |
| 04.04 | 1 | 2016/05/03 | mvdeventer | Fix comms, prevent collision on the start bit |
| 04.05 | 1 | 2018/05/24 | mvdeventer | Fix setup menu SDO not send to correct device type (Onboard master) |
| 04.06 | 1 | 2018/05/24 | mvdeventer | First CO2 version,don't work with occupancy sensor |
| 04.07 | 1 | 2018/05/24 | mvdeventer | Fix min max value from SDO 57 |
| 04.08 | 1 | 2018/12/05 | mvdeventer | Update for new (fancoil) LCD Implement CO2 comfort control Implement CO2 control Limit CO2 value to 1999 ppm |
| 04.09 | 1 | 2019/07/16 | mvdeventer | Make occupancy sensor work again |
| 04.10 | 1 | 2019/07/16 | mvdeventer | Fix occupancy timeout |
| 04.11 | 1 | 2019/07/17 | mvdeventer | Only read occupancy sensor if diffuser comms is idle(prevent possible false triggers) |
| 04.12 | 1 | 2019/08/08 | mvdeventer | Rework occupancy delays 1 and 2. If the delay is set 0 don't do the action |
| 04.13 | 1 | 2019/08/12 | mvdeventer | Occupancy Icon must be on when "OccupancyOverride?" is to "occupied" |
| 04.14 | 1 | 2019/11/21 | mvdeventer | Flash CO2 top left when CO2 override active Add CO2 Menus to display current CO2, CO2 setpoint high and CO2 setpoint low |
| 04.15 | 1 | 2020/06/05 | mvdeventer | Reduce noise in changeover sensor samples |
| 04.16 | 1 | 2020/10/14 | mvdeventer | First relative humidly(RHT) sensor release |
| 04.17 | 1 | 2020/10/20 | mvdeventer | Add error recovery for RHT readings |
| 04.18 | 1 | 2020/10/22 | mvdeventer | Add RHT display setup bit |
| 04.19 | 1 | 2020/12/17 | mvdeventer | Corrected network startup time, needed for Fancoil MultiZone? compatibility |
| 04.19 | 1 | 2020/12/17 | mvdeventer | Do not display CO2 or RHT in menus if they are not installed |
| 04.20 | 1 | 2021/02/24 | mvdeventer | Implement new CO2 sensor |
| 04.20 | 1 | 2021/02/24 | mvdeventer | Add override status SDO 75(CO2 or RHT override) |
| 04.20 | 1 | 2021/02/24 | mvdeventer | Fix Blank LCD srceen (defect report: BT0061-0001) |
| 04.20 | 1 | 2021/02/24 | mvdeventer | Set default occupancy delays to 0 |
| 04.20 | 1 | 2021/02/24 | mvdeventer | Display override values(CO2 or RHT) when in override on LCD |
| 04.21 | 1 | 2021/03/01 | mvdeventer | Changes for production process when CO2 is fitted |
| 04.21 | 1 | 2021/03/01 | mvdeventer | Fix CO2 sensor comms |
| 04.22 | 1 | 2021/03/12 | christo.malan | Add some network lock functions(not used) |
| 04.23 | 1 | 2021/03/12 | mvdeventer | Fix compatibly with old CO2 and occupancy sensors |
| 04.24 | 1 | 2021/03/23 | mvdeventer | Limit CO2 LCD displayed to 1999 |
| 04.25 | 1 | 2021/03/24 | mvdeventer | Changes for production process when CO2 is fitted |
| 04.26 | 1 | 2021/04/26 | christo.malan | Network lock release DM0073-0015 |
| 04.27 | 1 | 2021/08/29 | christo.malan | Allow CO2 setpoint to be changed when set to always display CO2 Make setpoint edit time out after 5s |
| 04.28 | 1 | 2021/10/28 | christo.malan | Hot start release DM0073-0018 |
| 04.29 | 1 | 2021/11/15 | christo.malan | Slowdown LCD temperature update |
| 04.30 | 1 | 2021/11/15 | martin.vdeventer | Add NTC offset code |
| 04.31 | 1 | 2021/11/15 | martin.vdeventer | ProcData?.b_USE_NTC_TEMP_SENSOR = TRUE USE THE NTC for temp measurements |
| 04.32 | 1 | 2022/06/23 | martin.vdeventer | ProcData?.b_HumidityOffset implemented |
| 04.33 | 1 | 2022/07/05 | martin.vdeventer | Menu Updates |
| 04.33 | 1 | 2022/07/05 | martin.vdeventer | CO2 ventialtion setpoint can be set when the CO2 override is on screen |
| 04.33 | 1 | 2022/07/05 | martin.vdeventer | Change RHT to RH on LCD |
| 04.33 | 1 | 2022/07/05 | martin.vdeventer | Co2 setpoint high or temperature setpoint |
| 04.34 | 1 | 2022/07/14 | martin.vdeventer | Flash setpoints only when SDO 50 Edit setpoint Disable is false else dont flash |
| 04.34 | 1 | 2022/07/14 | martin.vdeventer | All LCD segment ON/OFF and flashing is done in lcd.c. Nothing in main loop |
| 04.35 | 1 | 2022/07/10 | martin.vdeventer | Sensirion SCD30 I2C default read values when started and polling added |