Version MinHW Date Done by Reason
04.00 1 2016/04/12mvdeventer New form factor and LCD
04.01 1 2016/04/12mvdeventer LCD driver updates
04.02 1 2016/04/18mvdeventer Add SDO 200 to turn on/off LCD ALL, for testing
04.03 1 2016/04/26mvdeventer Remove Rickard LOGO from button press on startup
04.04 1 2016/05/03mvdeventer Fix comms, prevent collision on the start bit
04.05 1 2018/05/24mvdeventer Fix setup menu SDO not send to correct device type (Onboard master)
04.06 1 2018/05/24mvdeventer First CO2 version,don't work with occupancy sensor
04.07 1 2018/05/24mvdeventer Fix min max value from SDO 57
04.08 1 2018/12/05mvdeventer Update for new (fancoil) LCD
Implement CO2 comfort control
Implement CO2 control
Limit CO2 value to 1999 ppm
04.09 1 2019/07/16mvdeventer Make occupancy sensor work again
04.10 1 2019/07/16mvdeventer Fix occupancy timeout
04.11 1 2019/07/17mvdeventer Only read occupancy sensor if diffuser comms is idle(prevent possible false triggers)
04.12 1 2019/08/08mvdeventer Rework occupancy delays 1 and 2. If the delay is set 0 don't do the action
04.13 1 2019/08/12mvdeventer Occupancy Icon must be on when "OccupancyOverride?" is to "occupied"
04.14 1 2019/11/21mvdeventer Flash CO2 top left when CO2 override active
Add CO2 Menus to display current CO2, CO2 setpoint high and CO2 setpoint low
04.15 1 2020/06/05mvdeventer Reduce noise in changeover sensor samples
04.16 1 2020/10/14mvdeventer First relative humidly(RHT) sensor release
04.17 1 2020/10/20mvdeventer Add error recovery for RHT readings
04.18 1 2020/10/22mvdeventer Add RHT display setup bit
04.19 1 2020/12/17mvdeventer Corrected network startup time, needed for Fancoil MultiZone? compatibility
04.19 1 2020/12/17mvdeventer Do not display CO2 or RHT in menus if they are not installed
04.20 1 2021/02/24mvdeventer Implement new CO2 sensor
04.20 1 2021/02/24mvdeventer Add override status SDO 75(CO2 or RHT override)
04.20 1 2021/02/24mvdeventer Fix Blank LCD srceen (defect report:BT0061-0001)
04.20 1 2021/02/24mvdeventer Set default occupancy delays to 0
04.20 1 2021/02/24mvdeventer Display override values(CO2 or RHT) when in override on LCD
04.21 1 2021/03/01mvdeventer Changes for production process when CO2 is fitted
04.21 1 2021/03/01mvdeventer Fix CO2 sensor comms
04.22 1 2021/03/12christo.malanAdd some network lock functions(not used)
04.23 1 2021/03/12mvdeventer Fix compatibly with old CO2 and occupancy sensors
04.24 1 2021/03/23mvdeventer Limit CO2 LCD displayed to 1999
04.25 1 2021/03/24mvdeventer Changes for production process when CO2 is fitted