| 1 | | ||= Version =||= MinHW =||= Date =||= Done by =||= Reason =|| || |
| 2 | | ||04.00 || 1 ||2016/04/12||mvdeventer ||New form factor and LCD || |
| 3 | | ||04.01 || 1 ||2016/04/12||mvdeventer ||LCD driver updates|| |
| 4 | | ||04.02 || 1 ||2016/04/18||mvdeventer ||Add SDO 200 to turn on/off LCD ALL, for testing|| |
| 5 | | ||04.03 || 1 ||2016/04/26||mvdeventer ||Remove Rickard LOGO from button press on startup|| |
| 6 | | ||04.04 || 1 ||2016/05/03||mvdeventer ||Fix comms, prevent collision on the start bit|| |
| 7 | | ||04.05 || 1 ||2018/05/24||mvdeventer ||Fix setup menu SDO not send to correct device type (Onboard master)|| |
| 8 | | ||04.06 || 1 ||2018/05/24||mvdeventer ||First CO2 version,don't work with occupancy sensor|| |
| 9 | | ||04.07 || 1 ||2018/05/24||mvdeventer ||Fix min max value from SDO 57|| |
| 10 | | ||04.08 || 1 ||2018/12/05||mvdeventer ||Update for new (fancoil) LCD \\Implement CO2 comfort control \\Implement CO2 control \\Limit CO2 value to 1999 ppm|| |
| 11 | | ||04.09 || 1 ||2019/07/16||mvdeventer ||Make occupancy sensor work again|| |
| 12 | | ||04.10 || 1 ||2019/07/16||mvdeventer ||Fix occupancy timeout|| |
| 13 | | ||04.11 || 1 ||2019/07/17||mvdeventer ||Only read occupancy sensor if diffuser comms is idle(prevent possible false triggers)|| |
| 14 | | ||04.12 || 1 ||2019/08/08||mvdeventer ||Rework occupancy delays 1 and 2. If the delay is set 0 don't do the action|| |
| 15 | | ||04.13 || 1 ||2019/08/12||mvdeventer ||Occupancy Icon must be on when "OccupancyOverride" is to "occupied"|| |
| 16 | | ||04.14 || 1 ||2019/11/21||mvdeventer ||Flash CO2 top left when CO2 override active \\Add CO2 Menus to display current CO2, CO2 setpoint high and CO2 setpoint low|| |
| 17 | | ||04.15 || 1 ||2020/06/05||mvdeventer ||Reduce noise in changeover sensor samples|| |
| 18 | | ||04.16 || 1 ||2020/10/14||mvdeventer ||First relative humidly(RHT) sensor release|| |
| 19 | | ||04.17 || 1 ||2020/10/20||mvdeventer ||Add error recovery for RHT readings|| |
| 20 | | ||04.18 || 1 ||2020/10/22||mvdeventer ||Add RHT display setup bit|| |
| 21 | | ||04.19 || 1 ||2020/12/17||mvdeventer ||Corrected network startup time, needed for Fancoil MultiZone compatibility|| |
| 22 | | ||04.19 || 1 ||2020/12/17||mvdeventer ||Do not display CO2 or RHT in menus if they are not installed|| |
| 23 | | ||04.20 || 1 ||2021/02/24||mvdeventer ||Implement new CO2 sensor || |
| 24 | | ||04.20 || 1 ||2021/02/24||mvdeventer ||Add override status SDO 75(CO2 or RHT override)|| |
| 25 | | ||04.20 || 1 ||2021/02/24||mvdeventer ||Fix Blank LCD srceen (defect report:BT0061-0001)|| |
| 26 | | ||04.20 || 1 ||2021/02/24||mvdeventer ||Set default occupancy delays to 0|| |
| 27 | | ||04.20 || 1 ||2021/02/24||mvdeventer ||Display override values(CO2 or RHT) when in override on LCD|| |
| 28 | | ||04.21 || 1 ||2021/03/01||mvdeventer ||Changes for production process when CO2 is fitted|| |
| 29 | | ||04.21 || 1 ||2021/03/01||mvdeventer ||Fix CO2 sensor comms|| |
| 30 | | ||04.22 || 1 ||2021/03/12||christo.malan||Add some network lock functions(not used)|| |
| 31 | | ||04.23 || 1 ||2021/03/12||mvdeventer ||Fix compatibly with old CO2 and occupancy sensors|| |
| 32 | | ||04.24 || 1 ||2021/03/23||mvdeventer ||Limit CO2 LCD displayed to 1999|| |
| 33 | | ||04.25 || 1 ||2021/03/24||mvdeventer ||Changes for production process when CO2 is fitted|| |
| | 1 | ||= Version =||= MinHW =||= Date =||= Done by =||= Reason =|| || |
| | 2 | ||04.00 || 1 || 2016/04/12 ||mvdeventer ||New form factor and LCD || |
| | 3 | ||04.01 || 1 || 2016/04/12 ||mvdeventer || LCD driver updates || |
| | 4 | ||04.02 || 1 || 2016/04/18 ||mvdeventer || Add SDO 200 to turn on/off LCD ALL, for testing || |
| | 5 | ||04.03 || 1 || 2016/04/26 ||mvdeventer || Remove Rickard LOGO from button press on startup || |
| | 6 | ||04.04 || 1 || 2016/05/03 ||mvdeventer || Fix comms, prevent collision on the start bit || |
| | 7 | ||04.05 || 1 || 2018/05/24 ||mvdeventer || Fix setup menu SDO not send to correct device type (Onboard master) || |
| | 8 | ||04.06 || 1 || 2018/05/24 ||mvdeventer || First CO2 version,don't work with occupancy sensor || |
| | 9 | ||04.07 || 1 || 2018/05/24 ||mvdeventer || Fix min max value from SDO 57 || |
| | 10 | ||04.08 || 1 || 2018/12/05 ||mvdeventer || Update for new (fancoil) LCD \\Implement CO2 comfort control \\Implement CO2 control \\Limit CO2 value to 1999 ppm || |
| | 11 | ||04.09 || 1 || 2019/07/16 ||mvdeventer || Make occupancy sensor work again || |
| | 12 | ||04.10 || 1 || 2019/07/16 ||mvdeventer || Fix occupancy timeout || |
| | 13 | ||04.11 || 1 || 2019/07/17 ||mvdeventer || Only read occupancy sensor if diffuser comms is idle(prevent possible false triggers) || |
| | 14 | ||04.12 || 1 || 2019/08/08 ||mvdeventer || Rework occupancy delays 1 and 2. If the delay is set 0 don't do the action || |
| | 15 | ||04.13 || 1 || 2019/08/12 ||mvdeventer || Occupancy Icon must be on when "OccupancyOverride" is to "occupied" || |
| | 16 | ||04.14 || 1 || 2019/11/21 ||mvdeventer || Flash CO2 top left when CO2 override active \\Add CO2 Menus to display current CO2, CO2 setpoint high and CO2 setpoint low || |
| | 17 | ||04.15 || 1 || 2020/06/05 ||mvdeventer || Reduce noise in changeover sensor samples || |
| | 18 | ||04.16 || 1 || 2020/10/14 ||mvdeventer || First relative humidly(RHT) sensor release || |
| | 19 | ||04.17 || 1 || 2020/10/20 ||mvdeventer || Add error recovery for RHT readings || |
| | 20 | ||04.18 || 1 || 2020/10/22 ||mvdeventer || Add RHT display setup bit || |
| | 21 | ||04.19 || 1 || 2020/12/17 ||mvdeventer || Corrected network startup time, needed for Fancoil MultiZone compatibility || |
| | 22 | ||04.19 || 1 || 2020/12/17 ||mvdeventer || Do not display CO2 or RHT in menus if they are not installed || |
| | 23 | ||04.20 || 1 || 2021/02/24 ||mvdeventer ||Implement new CO2 sensor || |
| | 24 | ||04.20 || 1 || 2021/02/24 ||mvdeventer || Add override status SDO 75(CO2 or RHT override) || |
| | 25 | ||04.20 || 1 || 2021/02/24 ||mvdeventer || Fix Blank LCD srceen (defect report:BT0061-0001) || |
| | 26 | ||04.20 || 1 || 2021/02/24 ||mvdeventer || Set default occupancy delays to 0 || |
| | 27 | ||04.20 || 1 || 2021/02/24 ||mvdeventer || Display override values(CO2 or RHT) when in override on LCD || |
| | 28 | ||04.21 || 1 || 2021/03/01 ||mvdeventer || Changes for production process when CO2 is fitted || |
| | 29 | ||04.21 || 1 || 2021/03/01 ||mvdeventer || Fix CO2 sensor comms || |
| | 30 | ||04.22 || 1 || 2021/03/12 || christo.malan || Add some network lock functions(not used) || |
| | 31 | ||04.23 || 1 || 2021/03/12 ||mvdeventer || Fix compatibly with old CO2 and occupancy sensors || |
| | 32 | ||04.24 || 1 || 2021/03/23 ||mvdeventer || Limit CO2 LCD displayed to 1999 || |
| | 33 | ||04.25 || 1 || 2021/03/24 ||mvdeventer || Changes for production process when CO2 is fitted || |
| | 34 | ||04.26 || 1 || 2021/04/26 || christo.malan || Network lock relase || |
| | 35 | ||04.27 || 1 || 2021/08/29 || christo.malan || Allow CO2 setpoint to be changed when set to always display CO2 [[BR]]Make setpoint edit time out 5s || |
| | 36 | |
| | 37 | |
| | 38 | |
| | 39 | ||04.28 || 1 || 2021/10/28 || christo.malan || Hot start [BR] || |
| | 40 | |
| | 41 | * remove Reset on wrong packet length |
| | 42 | * some hot start flags for master |
| | 43 | * Fix CRC for rx packet |
| | 44 | * reset after 3 watchdog time outs when poll master is removed |
| | 45 | * Reset without clearing BT_wPowerFalgs when sending resolve * |
| | 46 | |
| | 47 | ||04.29 || 1 ||2021/11/15 ||christo.malan || Slowdown LCD temperature update || |